§ 21.34.060. Site development standards.  


Latest version.
  • A.

    Minimum Building Site. The minimum building site is forty (40) acres unless otherwise shown on the Sectional District Map (e.g. "PG/160" would mean a minimum building site of one hundred sixty (160) acres).

    B.

    Structure Height and Setback Regulations. The following structure height and setback regulations apply unless superseded by a structure height limit noted on the zoning map (e.g. "PG/40 (24′)" would mean a structure height limit of twenty-four (24) feet), setback requirements when combined with a "B" District or setbacks shown on a recorded final or parcel maps, or setback lines on a Sectional District Map.

    1.

    Main Structures.

    a.

    Minimum Setbacks.

    Front: thirty (30) feet;

    Side: twenty (20) feet;

    Rear: twenty (20) feet.

    Maximum Height: thirty-five (35) feet.

    2.

    Accessory Structures (Habitable).

    a.

    Minimum Setbacks.

    Front: fifty (50) feet;

    Side: six feet;

    Rear: six feet.

    Maximum Height: thirty-five (35) feet.

    3.

    Accessory Structures (Non-habitable).

    a.

    Minimum Setbacks.

    Front: fifty (50) feet;

    Side: six feet;

    Rear: six feet.

    Maximum Height: thirty-five (35) feet.

    4.

    Wells, pumps, pump houses and associated facilities;

    a.

    Minimum Setbacks.

    Front: five feet;

    Side: five feet;

    Rear: five feet;

    Height: thirty-five (35) feet.

    b.

    Agricultural windmills and wind machines for crop protection are exempt from the height provisions of this Chapter.

    C.

    Minimum Distance Between Structures.

    Main Structures: ten (10) feet;

    Accessory/Main Structures: six feet;

    Accessory/Accessory: six feet.

    D.

    Building Site Coverage, Maximum: five percent, except for commercial greenhouse operations which are permitted a coverage of fifty (50) percent. Additional coverage for greenhouses may be permitted subject to a Use Permit. All other additions to coverage shall require a variance.

    E.

    Parking Regulations. All parking shall be established pursuant to Chapter 21.58.

    F.

    Landscaping Requirements. None, except as required as a condition of approval of an Administrative Permit or Use Permit.

    G.

    Lighting Requirements.

    1.

    For any new development that includes exterior lighting, all exterior lighting shall be consistent with the Design Guidelines for Exterior Lighting adopted by the Board of Supervisors pursuant to Section 21.63.020, unless exempt under Section 21.63.020.D.

    2.

    Review by the Director of Planning of all exterior lighting associated with any construction permit for consistency with the Design Guidelines for Exterior Lighting and approval by the Director of Planning are required prior to issuance of the construction permit.

    3.

    Applications for construction permits which are subject to these lighting regulations must include the following information:

    a.

    Plans indicating the location of each light fixture; and

    b.

    Manufacturer's catalog specification sheet for each type of fixture.

    c.

    The Director of Planning may waive these submittal requirements or request additional information, as deemed necessary on a project by project basis.

    H.

    Sign Regulations. Signing for all development shall be established pursuant to Chapter 21.60.

(Ord. No. 5262, § 15, 1-26-2016)